Symptoms:

  • Push belt slippage
  • Delayed engagement
  • Low pump volume

Cause:

Worn pump flow control valve and bore allow pump pressure to leak to low pressure side of pump.

Correction:

Ream the bore to restore circularity and size the diameter to establish functional clearances between the reamed bore and oversize valve. Functional clearances will eliminate pump pressure loss and slippage.
  • JF011E (RE0F10A), JF015E (RE0F11A), JF016E (RE0F10D), JF017E (RE0F10E) Oversized Pump Flow Control Valve 33510N-01
  • JF011E (RE0F10A), JF015E (RE0F11A), JF016E (RE0F10D), JF017E (RE0F10E) Oversized Pump Flow Control Valve 33510N-01

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

JF011E (RE0F10A), JF015E (RE0F11A), JF016E (RE0F10D), JF017E (RE0F10E) Oversized Pump Flow Control Valve Vacuum Test Locations