• U151E, U151F, U250E Remanufactured Valve Body TOY182

U151E/F, U250E Valve Body Identification

The valve bodies CANNOT be interchanged. The linear solenoids are different in size. The electrical connectors on the linear solenoids are different shapes and the internal harness will not plug into the wrong valve body.

Verify which version is required prior to installing a remanufactured valve body by:

Inspect the Solenoid Connectors

The electrical connectors on the linear solenoids are different shapes, so the internal harness will not plug in to the wrong valve body.

Gauge the Solenoid Size

The linear solenoids on the '01–'03 version of this valve body are larger in diameter than the '04–'16 version. A 7/8" open end wrench can be used as a "go/no go" gauge. The smaller linear solenoids on the '04–'16 version will fit into the open end of a 7/8" wrench, but the larger linear solenoids on the '01–'03 version will not.

'01–'03'04–'16


Part No. TOY182Part No. TOY181