Symptoms:

  • Planetary failure
  • Bushing failure
  • Lube failures
  • Overheating
  • Low converter pressure
  • Bump shifts
  • Flare shifts
  • Rough idle in Reverse
  • TCC apply & release concerns

Cause:

Excess wear at the lubrication control valve bore allows fluid to escape the circuit, resulting in lube-related failures and drivability concerns.

Correction:

Recover hydraulic control and renew lube circuit performance by reconditioning the bore and installing Sonnax oversized lubrication control valve kit.
  • 6R100, 6R60, 6R75, 6R80 (2009–2014), 6R80 (2015-Later), ZF6HP19, ZF6HP26, ZF6HP32 Oversized Lubrication Control Valve Kit 95740-11K
  • 6R100, 6R60, 6R75, 6R80 (2009–2014), 6R80 (2015-Later), ZF6HP19, ZF6HP26, ZF6HP32 Oversized Lubrication Control Valve Kit 95740-11K

You need this if...

Vacuum test(s) at the port(s) indicated fail to hold the recommended minimum in-Hg. 

6R100, 6R60, 6R75, 6R80 (2009–2014), 6R80 (2015-Later), ZF6HP19, ZF6HP26, ZF6HP32 Oversized Lubrication Control Valve Kit Vacuum Test Locations