Symptoms:

  • Converter shudder & TCC slip
  • Low converter pressure
  • Overheated converter
  • Damaged converter
  • Excess converter pressure

Cause:

Excess wear/clearance at the inboard converter limit valve spool leads to unwanted converter pressure loss. Debris damage at the outboard valve spool creates binding that can stick the valve in either a high or low converter pressure position.

Correction:

Recover hydraulic control and renew TCC performance by installing Sonnax drop-in converter limit valve kit that features extended valve lands to compensate for wear and excess clearance.
  • 4R70E, 4R70W, 4R75E, 4R75W, AODE Converter Limit Valve Kit 76948-56K
  • 4R70E, 4R70W, 4R75E, 4R75W, AODE Converter Limit Valve Kit 76948-56K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

4R70E, 4R70W, 4R75E, 4R75W, AODE Converter Limit Valve Kit Vacuum Test Locations