Symptoms:

  • Chatter on acceleration
  • High line pressure
  • Low line pressure
  • Pulley breakage
  • Slips in Forward & Reverse

Cause:

Excess bore and valve train component wear allows critical oil volume/pressure to escape the circuit. Wear about the smaller valve spool can lead to excess oil pressure at the primary pulley actuator. Conversely, wear about the larger spools and end plug may cause insufficient oil pressure to the primary pulley actuator.

Correction:

Restore proper hydraulic operation by refurbishing the bore and installing Sonnax's oversized primary pulley reducing valve kit.
  • JF016E (RE0F10D) Oversized Primary Pulley Reducing Valve Kit 33510N-03K
  • JF016E (RE0F10D) Oversized Primary Pulley Reducing Valve Kit 33510N-03K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

JF016E (RE0F10D) Oversized Primary Pulley Reducing Valve Kit Vacuum Test Locations