Symptoms:

  • Poor shift quality
  • Flare shifts
  • Harsh shifts
  • Erratic line pressure
  • Slips in Forward & Reverse
  • Delayed Reverse
  • No Reverse
  • TCC slip

Cause:

Excess valve and bore clearance allows critical line pressure to exhaust causing high or low pressure depending on the location of the wear.

Correction:

Sonnax oversized valve and tool kits restore the correct valve/bore clearances and line pressure control as well as prevent future wear in this area.
  • 6R100, 6R80 (2015-Later) Oversized Pressure Regulator Valve Kit 95740-46K
  • 6R100, 6R80 (2015-Later) Oversized Pressure Regulator Valve Kit 95740-46K
  • 6R100, 6R80 (2015-Later) Oversized Pressure Regulator Valve Kit 95740-46K details
  • 6R100, 6R80 (2015-Later) Oversized Pressure Regulator Valve Kit 95740-46K details

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

6R100, 6R80 (2015-Later) Oversized Pressure Regulator Valve Kit Vacuum Test Locations