Symptoms:

  • Excess endplay

Cause:

After resurfacing the pump, a thicker washer than OE is needed to set correct endplay.

Correction:

Restore acceptable endplay by installing thicker Sonnax selective pump thrust washer.
  • 6L45, 6L50, 6L80, 6L90 Selective Pump Thrust Washer 33452A
  • 6L45, 6L50, 6L80, 6L90 Selective Pump Thrust Washer 33452A details