Symptoms:

  • Harsh shifts
  • Shift codes
  • Shift concerns

Cause:

Wear at the valve/sleeve bore allows critical control pressures to cross-leak between valve body circuits or escape to the sump. Accumulator control pressure may be high or low depending on wear location.

Correction:

Sonnax drop-in accumulator control plunger valve kit ends cross-leaks caused by wear and contains hydraulic pressure in the intended circuits. Pressure loss to the sump caused by worn components is eliminated.
  • A750E, A750F, A760E, A760F, A760H, A761E, A960E, A960F, AB60E, AB60F Accumulator Control Plunger Valve Kit 147741-43K
  • A750E, A750F, A760E, A760F, A760H, A761E, A960E, A960F, AB60E, AB60F Accumulator Control Plunger Valve Kit 147741-43K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

A750E, A750F, A760E, A760F, A760H, A761E, A960E, A960F, AB60E, AB60F Accumulator Control Plunger Valve Kit Vacuum Test Locations