Symptoms:

  • Overheated fluid
  • RPM surge on coast
  • Harsh downshifts
  • TCC apply & release concerns
  • TCC codes
  • Poor fuel economy

Cause:

Bore wear at the TCC apply valve allows critical pressure loss that prevents proper TCC operation.

Correction:

Recover hydraulic control and restore normal TCC action by reconditioning the bore and installing Sonnax oversized TCC apply valve.
  • ZF5HP19 Oversized TCC Apply Valve 85755-08
  • ZF5HP19 Oversized TCC Apply Valve 85755-08
  • ZF5HP19 Oversized TCC Apply Valve 85755-08 details

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

ZF5HP19 Oversized TCC Apply Valve Vacuum Test Locations