Symptoms:

  • Low pressure
  • Pump damaged
  • Pump slide wear
  • Gear ratio codes
  • No 4-5

Cause:

Wear at the main pressure regulator bore causes instability in decrease oil and balance oil.

Correction:

Sonnax pressure regulator valve enables the repair of the pressure regulator bore, returning stability to decrease oil and balance oil.
  • 5L40-E, 5L50-E Pressure Regulator Valve Kit 55211-08K
  • 5L40-E, 5L50-E Pressure Regulator Valve Kit 55211-08K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

5L40-E, 5L50-E Pressure Regulator Valve Kit Vacuum Test Locations