Symptoms:

  • TCC apply & release concerns
  • Burnt TCC apply components
  • Overheated transmission
  • Bushing wear

Cause:

Oscillation of the steel secondary pressure regulator valve within the aluminum casting causes wear, which will allow converter feed oil to leak to exhaust and not supply the lube circuit, resulting in converter complaints, burnt apply components and lube-related failures.

Correction:

Restore proper hydraulic control by reconditioning the bore and replacing worn valve with Sonnax oversized secondary pressure regulator valve kit.
  • A340E, A340H Oversized Secondary Pressure Regulator Valve Kit 97741-17K
  • A340E, A340H Oversized Secondary Pressure Regulator Valve Kit 97741-17K
  • A340E, A340H Oversized Secondary Pressure Regulator Valve Kit 97741-17K details

You need this if...

A340E, A340H Oversized Secondary Pressure Regulator Valve Kit Vacuum Test Locations