Symptoms:

  • RPM surge on acceleration
  • Chatter on acceleration
  • Push belt slippage & pulley fracture

Cause:

Loss of pressure control to the secondary pulley. Low pressure to the pulley causes chatter, push belt slip, surface fretting and metal contamination. With low pressure, pully diameter will not change and ratio remains the same.

Correction:

Refurbish the bore using the Sonnax tool kit and install the Sonnax secondary pulley control valve kit.
  • JF010E (RE0F09A/RE0F09B) Oversized Secondary Pulley Control Valve Kit 113741-17K
  • JF010E (RE0F09A/RE0F09B) Oversized Secondary Pulley Control Valve Kit 113741-17K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

JF010E (RE0F09A/RE0F09B) Oversized Secondary Pulley Control Valve Kit Vacuum Test Locations