Symptoms:

  • 1-2 Flare
  • 2nd Slip
  • 5-6 Flare
  • 6th Slip
  • B1 band burned
  • Gear ratio & solenoid codes

Cause:

Wear at the B1 band control valve bore affects apply and release rate of the servo.

Correction:

Sonnax B1 band control valve kit corrects circuit pressure loss and restores control of brake apply and release.
  • TF-80SC, TF-81SC B1 Band Control Valve Kit 39741-22K
  • TF-80SC, TF-81SC B1 Band Control Valve Kit 39741-22K
  • TF-80SC, TF-81SC B1 Band Control Valve Kit 39741-22K

You need this if...

Vacuum testing at the port(s) indicated fails to hold the recommended minimum in-Hg, or if wear is visually detected.

TF-80SC, TF-81SC B1 Band Control Valve Kit Vacuum Test Locations